BIMIO · Preflight
NO-GO
NO-GO — 10 blocker(s), 22 warning(s) across 20 sheet(s).
Generated 2026-08-29 09:14

Viewport titles

collisions, off-sheet drift, gap/length deviations, dishonest custom scales
GAP“Level 00 — GA Plan” gap 8.4 mm
A-101 · standard 5 mm (±0.5)
LENGTH“Level 00 — GA Plan” line 268.0 mm
A-101 · viewport width 291.4 mm
OVERLAP“Level 03 — Podium Roof Plan” title collides with viewport of “Podium Roof — Enlarged Plan”
A-104
GAP“Podium Roof — Enlarged Plan” gap 2.1 mm
A-104 · standard 5 mm (±0.5)
SCALE“Podium — Fire Strategy” scale text ‘1:100’
A-106 · view is 1:200
OFF-SHEET“Egress — Podium Level 01” title leaves the sheet
A-107
POSITION“Egress — Ground Level” title not below its viewport
A-107
LENGTH“Typical Residential — Key Plan” line 96.0 mm
A-200 · viewport width 142.5 mm
OFF-SHEET“Level 01M — GA Plan” viewport leaves the sheet
A-203
OVERLAP“Level 06 — GA Plan” title collides with title of “Level 06 — Core Enlarged Plan”
A-208
GAP“Level 06 — Core Enlarged Plan” gap 11.0 mm
A-208 · standard 5 mm (±0.5)
GAP“Level 12 — GA Plan” gap 3.6 mm
A-214 · standard 5 mm (±0.5)
SCALE“Level 17 — GA Plan” scale text ‘1:50’
A-219 · view is 1:100
LENGTH“East Elevation — Block A” line 402.0 mm
A-301 · viewport width 380.0 mm

Set integrity

references leaving the package, temp view modes, missing templates, empty sheets
NO TEMPLATE“Level -01 — GA Plan” has no view template — graphics are unguarded
A-103
callout“Level -01 — GA Plan” points to “Basement Waterproofing — Detail 3”
A-103 · NOT ON ANY SHEET
TEMP MODE“Level 22 — Roof Plan” is in Temporary Hide/Isolate — hidden elements will NOT print
A-105
section“Podium — Fire Strategy” points to “Section C-C”
A-106 · on A-312 (OUTSIDE the set)
callout“Typical Core — Riser Plan” points to “Riser Enclosure — Detail 1”
A-201 · on A-408 (OUTSIDE the set)
callout“Typical Core — Riser Plan” points to “Riser Enclosure — Detail 2”
A-201 · on A-408 (OUTSIDE the set)
elevation“Level 02 — GA Plan” points to “Lobby — Internal Elevation A”
A-204 · NOT ON ANY SHEET
TEMP MODE“Level 05 — GA Plan” has temporary view properties applied
A-207
NO TEMPLATE“Level 10 — GA Plan” has no view template — graphics are unguarded
A-212
section“Level 10 — GA Plan” points to “Section D-D — Podium”
A-212 · on A-313 (OUTSIDE the set)
view reference“Level 19 — GA Plan” points to “Level 19 — Balcony Setting-out”
A-221 · NOT ON ANY SHEET
EMPTY SHEETPlaceholder sheet — nothing prints
A-223
NO TEMPLATE“North Elevation — Block A” has no view template — graphics are unguarded
A-300
callout“North Elevation — Block A” points to “Curtain Wall Elevation — North Podium”
A-300 · on A-340 (OUTSIDE the set)

Revisions

every sheet should carry the latest revision (seq 4 “C03 — Stage 4 issue”)
NO REV“A-203 — Level 1 Mezzanine Plan” does not carry the latest revision
latest is seq 4 “C03 — Stage 4 issue”
NO REV“A-217 — Level 15 Plan” does not carry the latest revision
latest is seq 4 “C03 — Stage 4 issue”
NO REV“A-223 — Level 21 Plan” does not carry the latest revision
latest is seq 4 “C03 — Stage 4 issue”
LEGEND CLOUDA revision cloud sits on the legend “Fire Strategy — Legend”
a cloud on a legend does NOT put the revision on the sheet the legend is placed on